filtered by: All Types » All Clinical Topics » All Hot Topics » kidney

Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study

posted by Sebastian Leschka, M.D. | Apr 4, 2011
Sebastian Leschka, M.D.

To differentiate proxy renal cystic lesions containing protein, blood, iodine contrast, or saline solutions using dual-energy CT (DECT) equipped with a new tin filter technology (TFT). Read more

Article Series: Dual Energy CT – Scientific Evidence and Clinical Application (4/7) – Abdominal Imaging

posted by Thorsten R. C. Johnson, M.D. | Dec 10, 2010
Article Series: Dual Energy CT – Scientific Evidence and Clinical Application (4/7) – Abdominal Imaging

This article is part of the seven-article series on “Dual Energy CT – Scientific Evidence and Clinical Application”. T. Johnson talks about DE applications in abdominal imaging including aorta and plaque imaging. Read more

Performance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing masses

posted by Hatem Alkadhi, M.D. | Nov 8, 2010
Hatem Alkadhi, M.D.

To assess the performance of dual-energy computed tomography (DECT) equipped with the new tin filter technology to classify phantom renal lesions as cysts or enhancing masses. Read more

Exclusion of urolithiasis in the presence of contrast media using dual energy

posted by Axel Kuettner, M.D. | Aug 28, 2009
Axel Kuettner, M.D.
  • [1] Conventional 5 mm axial image of the lower pole of the kidneys. In the right kidney, the hyperenhancing area could be a calcified nodule.
  • exclusion-of-urolithiasis-in-the-presence-of-contrast-media-using-dual-energy-2[2] High resolution coronal reconstruction displays a nodular hyperenhancing nodule.
  • [3] High resolution sagittal reconstruction confirms the presence of a nodular hyperenhancing nodule, making the diagnosis of a renal calculus likely.
  • [4] Virtual non-enhanced analysis shows that the major component of the nodular formation is iodine, which is no longer present in the virtual non-enhanced image.

Case history: 45-year-old female with cholangiocellular carcinoma and known peritoneal carcinosis presents for follow-up scan post surgery and post chemotherapy. Question: Can virtual non-enhanced imaging confirm the presence of a small renal stone in the lower pole of the right kidney found incidentally? Read more

Protocol Dual Energy for the evaluation of urolithiasis

posted by Anno Graser, M. D. | Oct 23, 2008
Anno Graser, M. D.

Please, click on the title to see the protocol. Read more

DSCT for Evaluation of Urolithiasis

posted by Anno Graser, M. D. | Oct 23, 2008
Anno Graser, M. D.
  • spiral-de-1a.jpg
  • spiral-de-1b.jpg
  • spiral-de-2a.jpg
  • spiral-de-2b.jpg

History A 34 year-old female (A) and a 55 year-old male (B) patient were both referred for MDCT evaluation of a known urinary calculi. A non-enhanced MDCT scan of the abdomen was performed on the Dual Source CT (DSCT) using spiral Dual Energy evaluation. Diagnosis The Dual Energy acquisition allowed not only a … Read more

Dual Energy CT – Renal Stone Composition

posted by Savvas Nicolaou, M.D. | Sep 26, 2008
Savvas Nicolaou, M.D.

The following question has been sent by Dr. Ravi Mahal, Radiologist, Boca Radiology Group, USA: We have been using the DECT for Urinary stone composition for the past 6 months.  Recently I had a case where a patient had 2 stones of different compositions; a right uric acid stone and a … Read more